Intraoperative Measurement With a Smartphone App That Improves the Accuracy of Derotational Osteotomies

Keywords: Derotational osteotomy, surgical technique, intraoperative measurement, smartphone, apps

Abstract

Smartphone technology has created new opportunities to incorporate medical technology into daily clinical practice. Accurate intraoperative measurement of the desired derotation angle is a frequent challenge for the surgeon when performing derotational osteotomies. Divergent pins are commonly used proximal and distal to the osteotomy, which after derotation should remain parallel. However, the measurement of the derotation angle is usually performed by visual estimation, which could be unreliable. The aim of this study is to describe a technical detail that combines the application of divergent pins with intraoperative measurement by mobile phone to improve the accuracy of derotational osteotomies.

Downloads

Download data is not yet available.

Author Biographies

Andrés Ferreyra, Child Orthopedics and Traumatology Department, Sanatorio Allende, Córdoba, Argentina
Child Orthopedics and Traumatology Department, Sanatorio Allende, Córdoba, Argentina
Ramiro Olleac, Child Orthopedics Service, Hospital de Clínicas “Presidente Dr. Nicolás Avellaneda”, San Miguel de Tucumán, Argentina
Child Orthopedics Service, Hospital de Clínicas “Presidente Dr. Nicolás Avellaneda”, San Miguel de Tucumán, Argentina
Julio Javier Masquijo, Child Orthopedics and Traumatology Department, Sanatorio Allende, Córdoba, Argentina
Child Orthopedics and Traumatology Department, Sanatorio Allende, Córdoba, Argentina

References

Franko OI. Smartphone apps for orthopaedic surgeons. Clin Orthop Relat Res 2011;469:2042-8.

https://doi.org/10.1007/s11999-011-1904-0

Mobasheri MH, King D, Johnston M, Gautama S, Purkayastha S, Darzi A. The ownership and clinical use of

smartphones by doctors and nurses in the UK: a multicentre survey study. BMJ Innov 2015;1(4):174-81.

https://doi.org/10.1136/ bmjinnov-2015-000062

Al-Hadithy N, Gikas PD, Al-Nammari SS. Smartphones in orthopaedics. Int Orthop 2012;36(8):1543-7.

https:// doi.org/10.1007/s00264-012-1527-4

Behnoush B, Tavakoli N, Bazmi E, Nateghi Fard F, Pourgharib Shahi MH, Okazi A, et al. Smartphone and universal goniometer for measurement of elbow joint motions: a comparative study. Asian J Sports Med 2016;7(2):e30668. https://doi. org/10.5812/asjsm.30668

Ferriero G, Vercelli S, Sartorio F, Muñoz Lasa S, Ilieva E, Brigatti E, et al. Reliability of a smartphone-based

goniometer for knee joint goniometry. Int J Rehabil Res 2013;36(2):146-51. https://doi.org/10.1097/ MRR.0b013e32835b8269

Shen YF, Huang JH, Li XL, Gao H. Evaluation of the smartphone for measurement of femoral rotational deformity. ANZ J Surg 2019;(89):E422–E427. https://doi.org/10.1111/ans.15384

Franko OI, Bray C, Newton PO. Validation of a scoliometer smartphone App to assess scoliosis. Pediatr Orthop

;32:e72-e75. https://doi.org/10.1097/BPO.0b013e31826bb109

Balg F, Juteau M, Theoret C, Svotelis A, Grenier G. Validity and reliability of the iPhone to measure rib hump in

scoliosis. J Pediatr Orthop 2014;34:774-9. https://doi.org/10.1097/BPO.0000000000000195

Otter SJ, Agalliu B, Baer N, Hales G, Harvey K, James K, et al. Reliability of a smartphone goniometer application

compared with traditional goniometer for measuring first metatarsophalangeal joint dorsiflexion. J Foot Ankle Res 2015;8:30. https://doi.org/10.1186/s13047-015- 0088-3

Delgado ED, Schoenecker PL, Rich MM, Capelli AM. Treatment of severe torsional malalignment syndrome. J

Pediatr Orthop 1996;16(4):484-8. https://doi.org/10.1097/00004694-199607000-00012

Kolp D, Ziebarth K, Slongo T. [Rotation or derotation osteotomy of the tibia]. Oper Orthop Traumatol 2017;29(2):163-72. [En alemán] https://doi.org/10.1007/s00064-016-0473-5

Bae DS, Waters PM. External rotation humeral osteotomy for brachial plexus birth palsy. Tech Hand Up Extrem Surg 2007;11(1):8-14. https://doi.org/10.1097/01.bth.0000248359.14448.e6

Kozin SH. Medial approach for humeral rotational osteotomy in children with residual brachial plexus birth palsy. Oper Tech Orthop 2007;17:88-93. https://doi.org/10.1053/j.oto.2007.01.006

Peters FM, Gree R, Goldstein N, Frey CT. Improving acetabular cup orientation in total hip arthroplasty by using smartphone technology. J Arthroplasty 2012;27(7):1324-30. https://doi.org/10.1016/j.arth.2011.11.014

Graham D, Suzuki A, Reitz C, Saxena A, Kuo J, Tetsworth K. Measurement of rotational deformity: using a

smartphone application is more accurate than conventional methods. ANZ J Surg 2013;83:937-41.

https://doi.org/10.1111/ans.12371

Published
2021-12-16
How to Cite
Ferreyra, A., Olleac, R., & Masquijo, J. J. (2021). Intraoperative Measurement With a Smartphone App That Improves the Accuracy of Derotational Osteotomies. Revista De La Asociación Argentina De Ortopedia Y Traumatología, 86(6), 858-861. https://doi.org/10.15417/issn.1852-7434.2021.86.6.1283
Section
Nota técnica