Surgeon’s radiation exposure in distal radius fractures internal fixation

Main Article Content

Fernando Vanoli
Luciano Gentile
Santiago Luis Iglesias
Esteban Lobos Centeno
María Pilar Diaz
Christian Antonio Allende Nores

Abstract

IntroductionThe objective of this study was to provide reference values of the doses of radiation absorbed by surgeons during ORIFof distal radius fractures.MethodsWe prospectively evaluated two surgeons radiation exposure during distal radius fracture ORIF between May-December 2015; measured using three dosimeters; one placed on the surgeons thorax, a second one on their neck, and the third one on their dominant wrist. A relative radiation index for each surgery was calculated, to identify the differences between sites.ResultsWe evaluated 50 patients. Surgical procedure duration averaged 40 minutes (SD 2.06), and there were no statistically significant difference between both surgeons (p=0,0436). C-arm exposure time averaged 75 seconds. In global terms there were significant differences between surgeons (p = 0.007), or between sites (p<0,05), evidencing less radiation in the thorax0.04mSv (protected with a lead vest),than in the other two sites (not protected with lead)(wrist 0.017mSv and thyroid 0.18mSv).ConclusionThe radiation index constructed provides an indicator, which can be used to monitor and compare radiation dosages absorbed by surgeons. The amount of radiation exposure received by surgeons, when only distal radius fractures are considered, cannot be associated to increased risk of cancer or malignancy development.

Downloads

Download data is not yet available.

Metrics

Metrics Loading ...

Article Details

How to Cite
Vanoli, F., Gentile, L., Iglesias, S. L., Lobos Centeno, E., Diaz, M. P., & Allende Nores, C. A. (2017). Surgeon’s radiation exposure in distal radius fractures internal fixation. Revista De La Asociación Argentina De Ortopedia Y Traumatología, 82(4), 271-277. https://doi.org/10.15417/674
Section
Clinical Research
Author Biographies

Fernando Vanoli, SANATORIO ALLENDE

Instituto Allende de Cirugía Reconstructiva de los Miembros, Sanatorio Allende, Córdoba

Luciano Gentile, Sanatorio Allende

Instituto Allende de Cirugía Reconstructiva de los Miembros, Sanatorio Allende, Córdoba

Santiago Luis Iglesias, Sanatorio Allende

Instituto Allende de Cirugía Reconstructiva de los Miembros, Sanatorio Allende, Córdoba

Esteban Lobos Centeno, Sanatorio Allende

Instituto Allende de Cirugía Reconstructiva de los Miembros, Sanatorio Allende, Córdoba

María Pilar Diaz, Sanatorio Allende

Instituto Allende de Cirugía Reconstructiva de los Miembros, Sanatorio Allende, Córdoba

Christian Antonio Allende Nores, Sanatorio Allende

Instituto Allende de Cirugía Reconstructiva de los Miembros, Sanatorio Allende, Córdoba

References

1-Gutierrez Olivera N1, Ruchelli L2, Iglesias S2, Capomassi M3, Allende C4. Minimally invasive plate osteosynthesis in distal radius fractures with metaphyseal extension: A series of 13 cases. Chir Main. 2015 Oct;34(5):227-33. doi: 10.1016/j.main.2015.07.001. Epub 2015 Sep 7.

2-Mastrangelo G1, Fedeli U, Fadda E, Giovanazzi A, Scoizzato L, Saia B. Increased cancer risk among surgeons in an orthopaedic hospital. Occup Med (Lond). 2005 Sep;55(6):498-500.

3-Frazier TH1, Richardson JB, Fabré VC, Callen JP. Fluoroscopy-induced chronic radiation skin injury: a disease perhaps often overlooked. Arch Dermatol. 2007 May;143(5):637-40

4-Tuohy CJ1, Weikert DR, Watson JT, Lee DH. Hand and body radiation exposure with the use of mini C-arm fluoroscopy.J Hand Surg Am. 2011 Apr;36(4):632-8. doi: 10.1016/j.jhsa.2010.12.022. Epub 2011 Feb 23.

5- Chou LB1, Chandran S, Harris AH, Tung J, Butler LM. Increased breast cancer prevalence among female orthopedic surgeons. J Womens Health (Larchmt). 2012 Jun;21(6):683-9. doi: 10.1089/jwh.2011.3342. Epub 2012 Mar 20.

6-Henry AK: Extensile exposure, 2nd ed. Baltimore, Williams And Wilkins, 1970:100

7- Hafez MA1, Smith RM, Matthews SJ, Kalap G, Sherman KP. Radiation exposure to the hands of orthopaedic surgeons: are we underestimating the risk? Arch Orthop Trauma Surg. 2005 Jun;125(5):330-5. Epub 2005 Apr 21.

8-Cogan DG, Martin SF, Kimura SJ. Atom bomb cataracts. Science.1949;110(2868):654.

9-International Commission on Radiological Protection.ICRP Publication 60: 1990 Recommendations of the International Commission on Radiological Protection. Ann ICRP.1991;2:1–3.
10-Bekanntmachung der Neufassung der Röntgenverordnungvom 2003. Bundesgesetzblatt.2003;1:604–635.

11-Vañó E1, González L, Guibelalde E, Fernández JM, Ten JI. Radiation exposure to medical staff in interventional and cardiac radiology.Br J Radiol. 1998 Sep;71(849):954-60.

12-Faulkner K1, Harrison RM.Estimation of effective dose equivalent to staff in diagnostic radiology.Phys Med Biol. 1988 Jan;33(1):83-91.

13-Niklason LT1, Marx MV, Chan HP. Interventional radiologists: occupational radiation doses and risks.
Radiology. 1993 Jun;187(3):729-33.

14-Rampersaud YR1, Foley KT, Shen AC, Williams S, Solomito M. Radiation exposure to the spine surgeon during fluoroscopically assisted pedicle screw insertion. Spine (Phila Pa 1976). 2000 Oct 15;25(20):2637-45.

15-Mechlenburg I, Daugaard H, Soballe K. Radiation exposure to the orthopaedic surgeon during periacetabular osteotomy. IntOrthop. 2009;33:1747–1751.

16-Harstall R, Heini PF, Mini RL, Orler R. Radiation exposure to the surgeon during fluoroscopically assisted percutaneous vertebroplasty: a prospective study. Spine (Phila Pa 1976) 2005;30:1893–1898.

17- Singer G. Radiation exposure to the hands from mini C-arm fluoroscopy. J Hand Surg 2005; 30A: 795-17.

18-Thomson CJ, La Londe DH. Measurement of radiation exposure over a one-year period from Fluoroscan mini C-arm imaging unit.PlastReconstrSurg 2007; 119: 1147-8.

Most read articles by the same author(s)